Air Fed - 6 Pound Per Day

Air Fed - 6 Pound Per Day

Air Fed - 6 Pound Per Day

Water Cooled Ozone Options to Customize the Units: 


40 grams/per hour @ 2%, 25 LPM air at 20 PSI. water source required - 1.0 GPM @70 F. 230/1/60, 10
Amps
80 grams/per hour @5%, 15 LPM O2 at 20 PSI. water source required - 1.0 GPM @70 F. 230/1/60, 10
Amps
80 grams/per hour @ 2%, 50 LPM air at 20 PSI. water source required - 3.0 GPM @70 F. 230/1/60, 15
Amps
160 grams/per hour @5%, 30 LPM O2 at 20 PSI. water source required - 3.0 GPM @70 F. 230/1/60, 15
Amps
120 grams/per hour @ 2%, 100 LPM air at 20 PSI. water source required - 4.0 GPM @70 F. 230/1/60, 20
Amps.
240 grams/per hour @5% 40 LPM o2 at 20 PSI. water source required -4.0 GPM @70 F. 230/1/60, 20
Amps.

Feed gas requirements:
• Maximum dewpoint: -70 degree F.
• Minimum feed gas supply pressure: 40 PSI.

Cooling water requirements:
• Filtered prior to ozone generator.
• Maximum conductivity of
• Maximum hardness of
• Treated closed loop cooling highly recommended.

Standard:
• 50 or 60 Hz capable.
• Two customer interlocks.
• Variable output.
• Amp meter.
• Gas pressure switch.
• Gas flow meter.
• Cooling water flow meter.
• Cell cooling water temperature switch.
• Cabinet filter.
• Backflow prevention device.

Optional:
• Integrated ORP transmitter.
• Dewpoint analyzer.
• Air dryer.
• Air dryer pre filters.
• Oxygen concentrator